Spray Foam Insulation Products

Shop by Brand, Category or Keyword

NCFI 21-070 Rigid Pour Foam System
0
(0)

NCFI 21-070 Rigid Pour Foam System

NCFI 21-070 is a two component, HFO blown, low GWP, all PMDI based, pour-in-place urethane rigid foam system. It is designed for void filling applications which require a high degree of flow.


NCFI 21-075 Rigid Pour Foam System
0
(0)

NCFI 21-075 Rigid Pour Foam System

NCFI 21-075 is a two component, HFO blown, low GWP, all PMDI based, pour-in-place urethane rigid foam system. It is designed for void filling applications which require a high degree of flow. 


NCFI AgriThane 2.0# HFO Closed Cell Regular Foam
0
(0)

NCFI AgriThane 2.0# HFO Closed Cell Regular Foam

11-035 AgriThane is a two component, self-adhering, seamless, closed cell, spray applied polyurethane foam insulation system. This system has been formulated with highly insulating HFO as the blowing agent. 11-035 system is suitable for application on tanks and temperature controlled structures, and for air sealing structures as part of the NCFI AgriThane insulation system.


NCFI Enduratech 2.8# HFO Roofing Foam
0
(0)
NCFI Enduratech 2.8# HFO Roofing Foam

NCFI 10-016 is a two component, HFO blown spray polyurethane foam system designed for use as a self-adhering, seamless, high insulating, spray applied rigid polyurethane foam roofing system. 10-016 is available in multiple speeds for use in varying temperature conditions. 10-016 complies with ASTM D7425 and has been formulated to spray at a 2.8 pound density, depending on lift thickness, and may be used in applications of the EnduraTech® roofing systems.

NCFI Enduratech Q Acrylic Coating, 55 gal Drum
0
(0)
NCFI  Enduratech Acrylic Coatings, 55 gal drum

NCFI EnduraTech® Q (70-014) is a durable 100% acrylic elastomeric coating designed specifically for use over new spray polyurethane foam (SPF) roofing systems, or for recoating existing SPF roofing systems.

Installation:
  •  May be applied by spray or heavy nap roller. However, airless spray is recommended for consistency. 
  •  All surfaces must be clean, dry, and free of dirt, grease, oil, and other contaminants that would interfere with proper adhesion. 
  •  Apply in two separate coats at the minimum rate of one gallon per 100 square feet. 
  •  Apply at temperatures above 50°F. 
  •  Apply only when Weather conditions will permit coating to dry before rain, dew, or freezing temperatures occur.

NCFI Enduratech R Acrylic Coating, 55 gal Drum
0
(0)
NCFI Enduratech Acrylic R Coating, 55 gal Drum

NCFI Enduratech® R (70-012) is a durable 100% acrylic elastomeric coating designed specifically for use over new spray polyurethane foam (SPF) roofing systems, or for recoating existing SPF roofing systems.

Installation:

  •   May be applied by spray or heavy nap roller. However, airless spray is recommended for consistency.
  •   All surfaces must be clean, dry, and free of dirt, grease, oil, and other contaminants that would interfere with proper adhesion. 
  •   Apply in two separate coats at the minimum rate of one gallon per 100 square feet.
  •   Apply at temperatures above 50°F. 
  •   Apply only when Weather conditions will permit coating to dry before rain, dew, or freezing


NCFI Geo Terra-lok Fast Catalyst for Single Component, B Side, 1 Gallon Pail
0
(0)

NCFI Geo Terra-lok Fast Catalyst for Single Component, B Side, 1 Gallon Pail


NCFI TERRA LOK 24-120 Geo Foam is a low viscosity single component hydrophobic polyurethane used for increasing the load bearing capacity of loosely bound soils, filling voids and I/I mitigation. Ideal for stopping active or flowing water leaks and eliminating water seepage through cracks in stationary concrete structures and asset.

NCFI Geo Terra-Lok Regular Catalyst for Single Component, B Side, 5 Gallon Pail
0
(0)
NCFI Geo Terra-lok Regular Catalyst for Single Component, B Side, 5 Gallon Pail

NCFI TERRA LOK 24-120 Geo Foam is a low viscosity single component hydrophobic polyurethane used for increasing the load bearing capacity of loosely bound soils, filling voids and I/I mitigation. Ideal for stopping active or flowing water leaks and eliminating water seepage through cracks in stationary concrete structures and asset.

NCFI InsulBloc Optimaxx 2.0# HFO Closed Cell Foam
0
(0)

NCFI InsulBloc Optimaxx 2.0# HFO Closed Cell Foam

11-037 InsulBloc SmartSPF is a two component, self-adhering, seamless, closed cell, spray applied polyurethane foam insulation system. This system has been formulated with highly insulating HFO as the blowing agent. The InsulBlock SmartSPF insulation system is suitable for application on the exterior or interior side of Type I, Type II, Type III, IV and V building walls as well as other insulation applications.

Temperature Range Guideline: 40 degrees - 80 degrees F


NCFI InsulBloc Optimaxx 2.0# HFO Fast/Winter Closed Cell Foam
5.00
(1)
NCFI InsulBloc Optimaxx 2.0# HFO Winter Closed Cell Foam

11-037 InsulBloc SmartSPF is a two component, self-adhering, seamless, closed cell, spray applied polyurethane foam insulation system. This system has been formulated with highly insulating HFO as the blowing agent. The InsulBlock SmartSPF insulation system is suitable for application on the exterior or interior side of Type I, Type II, Type III, IV and V building walls as well as other insulation applications.

Cold Weather Foam. Temperature Range Guideline: 10 degrees - 50 degrees F

NCFI InsulStar Optimaxx 1.7# HFO Closed Cell Foam
0
(0)
NCFI InsulStar Optimaxx 1.7# HFO Closed Cell Foam- Temperature Range Guidelines: 40 -80 degrees

11-033 InsulStar®1.7 OPTIMAXX is a two component, self-adhering, seamless, closed cell, spray applied polyurethane foam system. This system has been formulated with a highly insulating HFO as the blowing agent. The InsulStar®1.7 OPTIMAXX insulation system is suitable for application on the interior building envelope of Type I, II, III, IV, & V buildings as well as other insulation applications.

NCFI InsulStar Optimaxx 1.7# HFO Fast/ Winter Closed Cell Foam
0
(0)

NCFI InsulStar Optimaxx 1.7# HFO Fast/Winter Closed Cell Foam-Temperature Range Guidelines: 10-50 degrees

11-033 InsulStar®1.7 OPTIMAXX is a two component, self-adhering, seamless, closed cell, spray applied polyurethane foam system. This system has been formulated with a highly insulating HFO as the blowing agent. The InsulStar®1.7 OPTIMAXX insulation system is suitable for application on the interior building envelope of Type I, II, III, IV, & V buildings as well as other insulation applications.


NCFI InsulStar Optimaxx 1.7# HFO Slow/Summer Closed Cell Foam
0
(0)
NCFI InsulStar Optimaxx 1.7# HFO Slow/Summer Closed Cell Foam-Temperature Range Guidelines: 70 degrees and up

11-033 InsulStar®1.7 OPTIMAXX is a two component, self-adhering, seamless, closed cell, spray applied polyurethane foam system. This system has been formulated with a highly insulating HFO as the blowing agent. The InsulStar®1.7 OPTIMAXX insulation system is suitable for application on the interior building envelope of Type I, II, III, IV, & V buildings as well as other insulation applications.

NCFI Isocyanate Terra-Lok Soil Stabilizer for Single Component, A Side, 4 Gallon Pail
0
(0)
 NCFI Isocyanate Terra-Lok Soil Stabilizer for Single Component, A Side, 4 Gallon Pail

NCFI TERRA LOK 24-120 Geo Foam is a low viscosity single component hydrophobic polyurethane used for increasing the load bearing capacity of loosely bound soils, filling voids and I/I mitigation. Ideal for stopping active or flowing water leaks and eliminating water seepage through cracks in stationary concrete structures and assets Based on the application, the 24-120 requires the use of REG or FAST catalyst.

NCFI Isocyanate Terra-Lok Soil Stabilizer for Single Component, A side, 55 Gallon Drum
0
(0)
NCFI Isocyanate Terra-Lok Soil Stabilizer for Single Component, A side, 55 Gal Drum

NCFI TERRA LOK 24-120 Geo Foam is a low viscosity single component hydrophobic polyurethane used for increasing the load bearing capacity of loosely bound soils, filling voids and I/I mitigation. Ideal for stopping active or flowing water leaks and eliminating water seepage through cracks in stationary concrete structures and assets Based on the application, the 24-120 requires the use of REG CAT or FAST CAT catalyst.

NCFI Open Cell Foam
0
(0)
NCFI Open Cell Foam-12-008

InsulStar® Light 12-008 is a two component, one-to-one by volume, no-mix, self-adhering, seamless spray applied open-cell polyurethane insulation system. InsulStar® Light has been formulated with water as the blowing agent and does not contain CFC, HCFC, HFC or formaldehyde. InsulStar® Light is suitable for use in Type I, II, III, IV & V construction.

NCFI Strata-Fill 24-023 Low Exotherm Polyurethane System
0
(0)
NCFI Strata-Fill 24-023 Low Exotherm Polyurethane System

Strata-Fill™ 24-023 is a two-component, HFO blown, MDI based, low-density, low exotherm polyurethane system formulated for void fill or trench-break applications. 24-023 has been formulated to process at 2.0-2.2 PCF, depending on lift thickness, without scorching or splitting.

NCFI Strata-Fill 24-028 Low Exotherm Polyurethane System
0
(0)

NCFI Strata-Fill 24-028 Low Exotherm Polyurethane System

NCFI 24-028 is a two-component, HFO blown, all MDIbased, nominal 2.0 pcf density, pour-in-place polyurethane foam system designed for Masonry Cavity Wall Fill. It could also be used as a void fill product for a variety of projects. NCFI 24-028 has low component viscosities making the system suitable for either mechanical mix machines, high pressure (over 600 psi) impingement mixing machines or for hand mixing.

Strata-Fil Polyurethanes 

About Strata-Fil Polyurethanes by NCFI are uniquely formulated, plural-component, low exotherm systems designed for a variety of geotechnical applications, such as void filling, structural forming, and cavity filling. Each batch goes through stringent testing and quality assurance standards to ensure reliability in the field. 


  • 1
  • 2